7  Installation and use procedures
7.3

Validate the safety functions

7.3.1

Validation

Once the system has been installed and configured, check that the safety functions are
activated/deactivated as expected and that the dangerous area is monitored by the system.
The LBK Designer application facilitates installation and configuration of the system, but the
validation process described below is still required.
7.3.2

Validate the access detection function

Example 1
Starting
conditions
Validation
procedure
Specifications
Example 2
Starting
conditions
Validation
procedure
Specifications
Leuze electronic GmbH + Co. KG
WARNING
Detection field dependency: Dependent mode
l
All the safety outputs activated
l
1. Access the first detection field .
2. Check that the system deactivates the safety output related to this detection field
and to the following fields (see Validate the system with LBK Designer on
page 72).
3. Move inside the area and check that the target position moves in the LBK Designer
app.
4. Repeat step 1 and 3 for each detection field .
5. If the safety outputs are not deactivated (see Troubleshooting validation on
page 72).
Access from several points with particular attention to the side areas of the field of
l
view and the limit areas (e.g. intersection with any side guards), see Example of
access points on the next page.
Access standing as well as crawling.
l
Access moving slowly and quickly.
l
Detection field dependency: Independent mode
l
All the safety outputs activated
l
1. Access the first detection field .
2. Check that the system deactivates only the safety output related to this detection
field (see Validate the system with LBK Designer on page 72).
3. Move inside the area and check that the target position moves in the LBK Designer
app.
4. Repeat step 1 and 3 for each detection field .
5. If the safety outputs are not deactivated (see Troubleshooting validation on
page 72).
Access from several points with particular attention to the side areas of the field of
l
view and the limit areas (e.g. intersection with any side guards), see Example of
access points on the next page.
Access standing as well as crawling.
l
Access moving slowly and quickly.
l
Sensor LBK SBV