9  Technical references
9.5.3

Restart signal

Part
Detection signal
1
Detection signal
2
Restart signal
CH1
Restart signal
CH2
Dt
Diff
Leuze electronic GmbH + Co. KG
The Detection signal 1 and Detection signal 2 outputs go to ON-state as soon as the
last channel has correctly completed the transition 0 -> 1 -> 0.
Interchangeable channel. Both channels of Restart signal must have a transition of
logical level 0 -> 1 ->0. The time they stay at high logical level (t) must be at least 200
ms.
Activation delay. Less than 50 ms.
Less than 100 ms. If the value is greater than 100 ms, the system maintains the outputs
deactivated.
Description
Sensor LBK SBV
112