8  Maintenance and troubleshooting
LED
S6
Steady red
S1–S6
Steady red
together
S1–S5
Steady red
together
S1–S4
Steady red
together
At least
Flashing red
one LED
At least
Flashing
one LED
green
All the
Steady
LEDs
orange
All the
Flashing
LEDs
green one
after the other
in sequence
Leuze electronic GmbH + Co. KG
LBK Designer application
Status
messages
FEE ERROR, FLASH
ERROR or RAM ERROR
FIELDBUS ERROR
DYNAMIC
CONFIGURATION ERROR
SENSOR
CONFIGURATION ERROR
See Sensor LED on the next
page
See Sensor LED on the next
page
-
-
Problem
Configuration
saving error,
configuration not
performed or
memory error
Communication
error on the
Fieldbus
Error in the selection
of the dynamic
configuration:
invalid ID
Error during the
configuration of the
sensors
Sensor
corresponding to the
flashing LED in error
** (seeSensor LED
on the next page)
Sensor
corresponding to the
flashing LED in error
** (seeSensor LED
on the next page)
The system is
starting up.
The controller is in
boot state.
Sensor LBK SBV
Solution
Reconfigure or configure the
system (see Manage the
configuration on page 73).
If the error persists, please
contact Technical Support.
At least one input or output
is configured as Fieldbus
controlled.
Check that the cable is
correctly connected,
communication with the host
is correctly established,
watchdog timeout is
configured correctly, and
exchanged data are not
maintained passivated.
Check the preset
configurations within the
LBK Designer application.
Check the sensors
connected and try again to
perform the configuration of
the system via the LBK
Designer application.
Check that the firmware of
the controller and sensors
are updated to compatible
versions.
Check the problem through
the LED on the sensor.
If the issue persists longer
than one minute, please
contact Technical Support.
Wait for a few seconds.
Open the latest available
version of the LBK Designer
application, connect to the
device and proceed with the
automatic recovery
procedure.
If the issue persists, please
contact Technical Support.