Sensor Led - Leuze electronic LBK SBV Original Operating Instructions

Safe radar system
Table of Contents

Advertisement

8  Maintenance and troubleshooting
LED
All LEDs Off
All LEDs Off
Note: fault signal on the controller (steady LED) takes priority over a faulty sensor signal. For the status of
the single sensor, check the sensor LED.
Note*: S1 is the first from the top.
Note**: S1 corresponds to the sensor with ID 1, S2 corresponds to the sensor with ID 2 and so on.
8.1.2

Sensor LED

Status
Steady
-
purple
Flashing
-
purple *
Flashing
CAN ERROR
red. Two
flashes
followed
by a pause
**
Flashing
CAN ERROR
red. Three
flashes
followed
by a pause
**
Flashing
SENSOR TEMPERATURE ERROR
red. Four
or SENSOR POWER ERROR
flashes
followed
by a pause
**
Leuze electronic GmbH + Co. KG
LBK Designer application
Status
messages
In Dashboard > System
status
icons
Progress icon
LBK Designer application
messages
Problem
Configuration not
yet applied to the
controller.
Configuration
transfer to the
controller in
progress.
Problem
Sensor in boot state
Contact Technical Support.
Sensor receiving a
Wait for the update to be
firmware update
completed without disconnecting
the sensor.
Sensor without a
Assign a Node ID to the sensor
valid identifier
(see Connect the controller to the
assigned
sensors on page 68).
Sensor does not
Verify the connection of all the
receive valid
sensors in the chain and check
messages from the
that the number of sensors
controller
configured in the LBK Designer
application is equal to the number
of the sensors physically
connected
Sensor in
Check the sensor connection and
temperature error or
that the cable length is within the
is receiving an
maximum limits. Verify that the
incorrect supply
temperature of the environment in
voltage
which the system is operating
conforms to the operating
temperatures listed in the
technical data in this manual.
Sensor LBK SBV
Solution
Configure the system.
Wait for the transfer to be
completed.
Solution
78