Error Events (Sensor); Introduction; Misconfiguration Error (Misconfiguration Error); Status Error And Fault (Status Error/Fault Error) - Leuze electronic LBK SBV Original Operating Instructions

Safe radar system
Table of Contents

Advertisement

8  Maintenance and troubleshooting
8.5
ERROR events (sensor)
8.5.1

Introduction

A diagnostic error is logged every time the periodic diagnostic functions detect a coming or going fault on
the LBK SBV-01 sensor.
8.5.2

Misconfiguration error (MISCONFIGURATION ERROR)

The misconfiguration error occurs when the sensor does not have a valid configuration or it has received an
invalid configuration from the controller.
8.5.3

Status error and fault (STATUS ERROR/FAULT ERROR)

The status error occurs when the sensor is in an internal invalid status or it has reached an internal fault
condition.
8.5.4

Protocol error (PROTOCOL ERROR)

The protocol error occurs when the sensor receives commands with an unknown format.
8.5.5
Sensor voltage errors (POWER ERROR)
Error
Sensor voltage
UNDERVOLTAGE
Sensor voltage
OVERVOLTAGE
The following table describes the sensor voltage:
Screen printing
VIN
V3.3
V1.2
V1.8
V1
8.5.6
Anti-tampering sensor (TAMPER ERROR)
Error
TILT ANGLE ERROR
ROLL ANGLE ERROR Sensor rotation around the z-axis
PAN ANGLE ERROR
Note: the information of the angle (in degrees) is reported.
Leuze electronic GmbH + Co. KG
Undervoltage error for the indicated voltage
Overvoltage error for the indicated voltage
Power supply voltage (+12 V DC)
Internal chip power supply voltage
Micro-controller power supply voltage
Internal chip power supply voltage (1.8 V)
Internal chip power supply voltage (1 V)
Sensor rotation around the x-axis
Sensor rotation around the y-axis
Meaning
Description
Meaning
Sensor LBK SBV
89