5  Functioning principles
Only when there are no restrictions does the function ensure that a person is detected when standing up
[D].
5.8.2

Types of managed restart

NOTICE
It is the responsibility of the machinery manufacturer to assess if automatic restart prevention
can guarantee the same level of safety as manual restart (as defined in standard EN ISO
13849-1:2015, section 5.2.2).
For each detection field independently, the system manages three types of restart prevention:
Type
Automatic
Manual
Leuze electronic GmbH + Co. KG
Conditions for enabling machinery restart
The time interval set through the LBK Designer application
(Restart timeout) has passed since the last motion
detection*.
The Restart signal was received correctly** (see Restart
signal on page 112).
Sensor LBK SBV
Safety working mode
allowed
All
Always-on access
detection
45