8  Maintenance and troubleshooting
Problem
The system does
not function
correctly
8.2

Event log management

8.2.1

Introduction

The event log recorded by the system can be downloaded from the LBK Designer application in a PDF file.
The system saves up to 4500 events, divided in two sections. In each section the events are displayed from
the most recent to the least recent. Above this limit, the oldest events are overwritten.
8.2.2

Download the system log

1. Start the LBK Designer application.
2. Click Settings and then Activity History.
3. Click DOWNLOAD LOG.
Note: to save the PDF, a printer must be installed on the computer.
8.2.3

Log file sections

The first line of the file reports the NID (Network ID) of the device and the date of the download.
The rest of the file log is divided in two sections:
Section
Description
1
Event log
2
Diagnostic
event log
8.2.4

Log line structure

Each line in the log file reports the following information, separated by tab character:
Timestamp (seconds counter from the latest boot)
l
Timestamp (absolute/relative value)
l
Event type:
l
[ERROR]= diagnostic event
o
o
[INFO]= information event
Source
l
o
CONTROLLER = if the event is generated by the controller
SENSOR ID = if the event is generated by a sensor. In this case is provided also the node ID of the
o
sensor.
Event description
l
Leuze electronic GmbH + Co. KG
Cause
Controller error
Sensor error
Content
Size
Information
3500 At every firmware update or on demand using the LBK
events
Error events
Error events
1000 Not possible
Check the status of the LEDs on the controller (see
Controller LED on page 76).
Access the application LBK Designer, on the
Dashboard page, mouse-over on
correspondence with the controller or the sensor.
Check the status of the LEDs on the sensor (see
Sensor LED on page 78).
Access the application LBK Designer, on the
Dashboard page, mouse-over on
correspondence with the controller or the sensor.
Designer application
Sensor LBK SBV
Solution
in
in
Reset
80