9  Technical references
With pulse
Part
Diff
Muting signal
(group n) CH 1
Muting signal
(group n) CH 2
Muting status
Dt
Leuze electronic GmbH + Co. KG
Less than 100 ms. If the value is greater than 100 ms, the diagnostic alarm starts and
the system deactivates the safety outputs.
Interchangeable channel.
Without pulse: enabled as long as both channels are at a high logic level (1), and
l
deactivated when both channels go to low logic level (0).
With pulse: enabled as long as both the input signals follow the configured muting
l
parameters (pulse width, period and phase shift).
Activation/deactivation delay. Without pulse less than 50 ms, with pulse less than three
times the period.
Description
Sensor LBK SBV
111