Planning for Remote Gateway 9150 unit installation

Mounting options

You can place the Remote Gateway 9150 unit on a desk or in a rack, or you can
mount it on the wall.
The Remote Gateway 9150 unit dimensions are
42.5 cm (17 in.) wide (without rack-mounting brackets)
29.4 cm (11.75 in.) deep
4.4 cm (1.75 in.) high
Mounting the Remote Gateway 9150 unit in a rack
If you want to install the Remote Gateway 9150 unit in a rack, the rack slot must
be large enough to provide air circulation to keep the Remote Gateway
9150 unit cool
allow you to securely fasten the Remote Gateway 9150 unit to the rack
using the rack-mount brackets
Mounting the Remote Gateway 9150 unit on the wall
If you want to install the Remote Gateway 9150 unit on the wall, you can mount
it so the cables from the rear panel are directed either right or left. Ensure that
the chosen location allows you to easily view the LED indicators on the front
panel.
ATTENTION!

Connections

The following connections are made from the rear panel of the Remote Gateway
9150 unit to the telephone and data networks:
Two 25-pair connectors (labeled TELCO 1 and TELCO 2) provide tip and
ring connections to stations (telephones) and central office trunks (ISDN
BRI). These connections provide the interface to the telephone network and
the PSTN.
52
You must complete wall installation using standard
telephony installation practices.
Remote Gateway 9150 Installation and Administration Guide