Remote Gateway 9150 Installation and Administration Guide
Definition
63
This log indicates a PSTN connection to a peer unit failed. This
could be caused by several possible problems, including:
1) A cabling issue at the Remote Gateway 9100 Series unit could
keep that unit from being able to connect on the PSTN.
2) The data port on the RLC could be disabled.
3) For BRI connections between a 9150 and an RLC the PSTN
path may not be a 64K clear channel (the required path).
4) Incorrect dial numbers could be keeping the circuit from
establishing.
5) Bit errors could be occurring preventing communication from
working. This could be due to bad cables or a bad connection.
MAJOR
TP
RLC, 9150, 911x
None
To check for the possible problems named above, do the following:
1) Check the PSTN connections at the Remote Gateway 9100
Series unit.
2) Confirm that the RLC's data port is enabled.
3) Confirm that BRI connections between a 9150 unit and its RLC
are 64K clear channel (the required path).
4) Confirm that the correct numbers are configured on both ends.
5) Confirm that cables and connections on both ends are good.
None
PSTN connection failed to initialize