04 Quick Connection Torch - ESAB THERMAL DINAMICS CUTMASTER 60i Operating Manual

Plasma cutting system
Hide thumbs Also See for THERMAL DINAMICS CUTMASTER 60i:
Table of Contents

Advertisement

CUTMASTER 60i
Mechanized Torch Ratings
Ambient
Temperature
100% @ 100 Amps @ 400
Duty Cycle
Maximum
Current
Voltage (V
)
peak
Arc Striking
Voltage
G.
Gas Requirements
Manual and Mechanized Torch Gas
Specifications
Gas (Plasma and Secondary) Compressed Air
Operating Pressure
Refer to NOTE
Maximum Input Pressure 125 psi / 8.6 bar
Gas Flow (Cutting and
Gouging)
WARNING
!
This Torch is not to be used with oxygen (O 2 ).
The SL60QD torch should not be used on an HF
system.
NOTE!
Operating pressure varies with torch model,
operating amperage, and torch leads length. Refer
to gas pressure settings charts for each model.
H.
Direct Contact Hazard
For standoff tip the recommended standoff
is 3/16 inches / 4.7 mm.
22
104° F
40° C
scfh
120 Amps
500V
500V
90 - 120 psi
6.2 - 8.3 bar
5 - 8.3 SCFM
300 - 500 scfh
142 - 235 lpm
INTRODUCTION
2T.04
Quick Connection Torch
The new SL60QD™ (Quick Disconnect) torch allows
for a quick change of the torch handle assembly
from the leads. To change the torch handle assem-
bly do the following.
1.
Remove the torch handle assembly by
grasping the torch handle in one hand
and the coupler nut and leads in the
other.
2.
Rotate the nut a minimum of one full
turn to the left (counter clockwise) and
pull the torch handle assembly out from
the leads in a straight line.
3.
To reattach, grasp both as before and
carefully align the internal connecting
parts.
4.
Carefully press the two together in a
straight line.
5.
Align the mark on the coupler nut with
that on the top of the torch handle and
rotate to the right (clockwise) drawing
the two together and seating the
connections inside. Do not use tools to
tighten.
0-5561

Advertisement

Table of Contents
loading

This manual is also suitable for:

A-14029

Table of Contents