DATE: January 22, 2004
TITLE/ PRODUCT NAME: Power Source Faults When Connecting
RATING:
_ _
X
_
X
_
PRODUCT SERIES/ MODEL:
ESAB 353cv, 453cv and 653cvcc Power Sources
Control Board PN 38129 & 38130
SERIAL NO:
All Serial Numbers
SUMMARY:
This Instruction will eliminate a nuisance power source fault light when connecting a DuraDrive
4-30 or 4-48 wire feeder. The fault condition is caused by a transient voltage spike in the 12
volt control circuit when power is applied to the DuraDrive feeder. An additional 22 microfarad
capacitor is added to increase the time constant of the power up reset circuit which eliminates
the false triggering of the fault light.
OPERATIONAL IMPACT:
None
www.esabna.com
DuraDrive Wire Feeder
DIRECTIVE
(Action is Required)
_
INFORMATION
(Action is Optional)
_
General Distribution
(Unrestricted)
BULLETIN NO: M-04-001
X
_
_ ALERT
(Potential Problem)
_ _
PRODUCT IMPROVEMENT
(Enhanced Product)
_ _
Business Confidential
(Restricted Distribution)

Advertisement

loading

Summary of Contents for ESAB 353cv

  • Page 1 General Distribution Business Confidential (Unrestricted) (Restricted Distribution) PRODUCT SERIES/ MODEL: ESAB 353cv, 453cv and 653cvcc Power Sources Control Board PN 38129 & 38130 SERIAL NO: All Serial Numbers SUMMARY: This Instruction will eliminate a nuisance power source fault light when connecting a DuraDrive 4-30 or 4-48 wire feeder.
  • Page 2 3. Solder the negative (-) lead to the end of R159 that is the emitter lead of transistor Q30 & Q31. 4. Re-install control PCB into power source. 22 microfarad 50 vdc capacitor PN -951013 CONTACT: ESAB Welding & Cutting Products Product & Service Information Group 843-664-4416 Phone 843-664-5539 FAX...

This manual is also suitable for:

453cv653cvcc3812938130