ESAB THERMAL DINAMICS CUTMASTER 60i Operating Manual page 27

Plasma cutting system
Hide thumbs Also See for THERMAL DINAMICS CUTMASTER 60i:
Table of Contents

Advertisement

3.
Use customer - supplied fittings to connect the air line to the Filter. A 5/16" (8mm) O.D.
smooth tubing should be used with the press in fitting.
NOTE!
Filter replacement part numbers can be found in Section 6 of this manual
Using High Pressure Air Cylinders
When using high pressure air cylinders as the air supply:
1.
Refer to the manufacturer's specifications for installation and maintenance procedures for
high pressure regulators.
2.
Examine the cylinder valves to be sure they are clean and free of oil, grease or any foreign
material. Briefly open each cylinder valve to blow out any dust which may be present.
3.
The cylinder must be equipped with an adjustable high - pressure regulator capable of outlet
pressures up to 120 psi (8.3 bar) maximum and flows of least 300-500 scfh / 5 - 8.3 CFM (142-
235 lpm).
4.
Connect supply hose to the cylinder.
NOTE!
Pressure should be set at 120 psi (8.3 bar) at the high pressure cylinder regulator.
0-5561
Outlet Port
(OUT)
2-Stage Filter
Inlet Port (IN)
5/16 (8mm)
O.D.
Gas
Supply Tubing
Art # A-13288
Optional Two - Stage Filter Installation
INSTALLATION
CUTMASTER 60i
Two Stage
Filter
Assembly
Air/Gas
Input
System Filter
Assembly
27

Advertisement

Table of Contents
loading

This manual is also suitable for:

A-14029

Table of Contents