Input Wiring Specifications Csa - ESAB Thermal Dynamics CUTMASTER 40 Operating Manual

Plasma cutting system
Table of Contents

Advertisement

2.05

Input Wiring Specifications CSA

1 Phase Input Cable Wiring Requirements
1 Phase CutMaster 40 Power Supply Input Cable Wiring Requirements
Input voltage
Volts
120 / 15A
120 / 20A
208
1 Phase
220
230
240
Line Voltages with Suggested Circuit Protection and Wire Sizes
Based on National Electric Code and Canadian Electric Code
NOTE!
Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.
Cable size is de-rated based on the Duty Cycle of the equipment.
NOTE!
Due to circuitry, age and condition two generators with the same ratings may produce different results. Adjust the
amperage accordingly.
Recommended
1/2"
0-5557
Freq
Power Input
Hz
kVA
50/60
2.3
50/60
3.1
50/60
6.1
50/60
6.1
50/60
6.0
50/60
6.0
CM 40 Cut Capacity
(12.7mm)
INTRODUCTION
Fuse
I max
I
eff
(amps)
1
19.3
13.6
15
25.3
18.3
20
29.2
18.5
50
27.9
17.6
50
26.1
16.5
50
25.1
15.9
50
Art# A-14359
Pierce
1/2"
(12.7mm)
CUTMASTER 40
Suggested Sizes
Flexible Cord
(Min. AWG)
12 AWG
12 AWG
12 AWG
12 AWG
12 AWG
12 AWG
Maximum
1" (25.4mm)
17

Advertisement

Table of Contents
loading