Fault Indicator

At initial power up, the system goes through a series of self checks before it is ready for use. If during
those checks it detects something is not within proper operating parameters, a fault will occur. If that
happens the Fault indicator
Error Code Indicator
Indicates when there is something that needs to be adjusted or repaired.
E001, E002, etc. Light up fault indicator also.
Error Code
E001 Over Temp
E002 Input Fault
E004 PIP Fault
E005 PIC Fault
E009 Fan Fault
E010 Low Output Current
E012 Output Fault
E014 Trigger Fault
E016 Pressure Fault
0-5561
will light followed by the Error Code
Description
Ambient temperature too high, duty cycle exceeded, fan failure
or other internal fault.
Input voltage outside the range of the unit or internal fault
resulting in low bus voltage.
1phase / 3phase jumpers J300 on Bias PCB set wrong.
Parts in Place fault. Shield cup not in place or tight.
Parts in Contact fault. Missing or worn tip/start cartridge or
electrode. Inlet pressure exceeds rating causing continuous gas
flow.
Fan failed or disconnected.
Work Lead current less than output current setting. Shorted
pilot switch or defective current sensor possible.
Tip to electrode voltage too low. Consumables fail to separate
when gas flows, start cartridge stuck, failed power supply, no
output or shorted torch body.
Torch trigger (start signal) active at start up.
Low Air/Gas pressure. Output pressure too low for selected
parameters.
SERVICE
CUTMASTER 60i
, and number in the digital display.