CUTMASTER 60i
5.
Set Mode Indicator
Indicator is ON when unit is flowing gas and pressure can be set.
6.
Shield Cup In Place Indicator
Indicator is Blinking when any of the following are not in place or connected: Shield Cup, ATC
leads or Quick Disconnect.
7.
Indicator is ON when unit is in "Gouge" mode and all Cutting Indicators (#8) are illuminated.
8.
Different segments will be illuminated to indicate different types of cutting.
• Gouging - All illuminated
• Normal Cutting and Latch Mode - Center indicator will be OFF.
• RAR (Rapid Auto Restart) Cutting - Every other indicator will be OFF.
• Set Mode - All indicators will be OFF.
9.
Fault Indicator
Indicator is ON when unit is in fault condition. See error codes appendix for fault light explanations.
Flashing when active. See Section 5.04 for more details.
Factory default: OFF
10.
EOL (End Of Life) Indicator
Indicator is normally OFF. It is also OFF during Drag Cutting.
When on it is to inform user that consumable failure is imminent
Active and/or operable in all cutting modes except Drag.
11.
Over Temp Indicator
Indicator is normally OFF. Indicator is ON/FLASHING when internal temperature exceeds normal
limits. Let the unit cool before continuing operation.
12.
Gas Pressure Indicator
Indicator used to show low, optimal and high gas pressure. Torch type, lead length, cutting mode
and amperage should all be set prior to setting the gas pressure. (90 - 125 PSI / 6.2 - 8.6 bar)
32
Gouge Mode Indicator
Type of Cutting Indicator
OPERATION
0-5561