The Stack Management page allows network managers to either reset the entire stack or a specific device. Device configuration changes that are
not saved before the device is reset are not saved. A unique Unit ID (1-6) identifies a stack member. This unit number determines the interface-level
configuration that the stack member uses. (The configuration is saved and managed by the master unit.). The stack management has the following defaults:
•
The stacking mode is set to stackable.
•
The stacking cable is copper.
•
The stacking numbering method is set to auto-numbering.
To configure stacking:
1.
Click Stack Management. The Stack Management Page opens.
The Stack Management Page contains the following fields:
•
Switch Stack Control from Unit 1 to Unit 2 — Switches the stack control from the Stack Master to the Backup Master. The possible field
values are:
Checked —Switches the stack control to the Standby Stack Master.
–
Unchecked — Maintains the current stacking control.
–
•
Stacking Ports — Allows the user to decide what cable type is in use.
Combo Ports Indicates that the combo port is used as the stacking port.
–
Copper Ports Indicates that the copper port is used as the stacking port.
–
•
Unit No. — Indicates the stacking member's current number. Possible values are 1-6.
•
Unit No. After Reset — Indicates the stacking member's future number after the stack is reset. Possible values are 1-6.