Current Number of Samples in List— Displays the current number of samples taken.
Owner — Displays the RMON station or user that requested the RMON information. The field range is 0-20 characters.
Delete — Removes History Control entries. The possible field values are:
Checked — Removes the selected History Control entry.
Unchecked — Maintains the current History Control entries.
2.
Click a history entry number. The Add History Control opens:
3.
Define the Source Interface, Owner, Sampling Interval, Max. No. of Samples to Keep, and Samples intervals fields.
4.
Click
. The entry is added to the History Control Page and the device is updated.
Viewing the RMON History Table
The History Table Page contains interface specific statistical network samples. Each table entry represents all counter values compiled during a
single sample. To view the: Viewing the RMON History Table
1.
Click Statistics/RMON > History Table. The History Table Page opens.
Figure 5 - 73: Add History Control Page