Configuring Rmon History - NETGEAR FS728TS User Manual

Netgear fs728ts: user guide
Hide thumbs Also See for FS728TS:
Table of Contents

Advertisement

Configuring RMON History

This section contains the following topics:
Defining RMON History Control
Viewing the RMON History Table
Defining RMON History Control
The History Control Page contains information about samples of data taken from ports. For example, the samples may include interface definitions
or polling periods. To view RMON history information:
1.
Click Statistics/RMON > RMON History > History Control. The History Control Page opens.
The History Control Page contains the following fields:
History Entry No. — Displays the entry number for the History Control Table page.
Source Interface — Displays the interface from which the history samples were taken. The possible field values are:
Port — Specifies the port from which the RMON information was taken.
LAG — Specifies the port from which the RMON information was taken.
Sampling Interval — Indicates in seconds the time that samples are taken from the ports. The field range is 1-3600. The default is 1800
seconds (equal to 30 minutes).
Samples Requested — Displays the number of samples to be saved. The field range is 1-65535. The default value is 50.
Figure 5 - 72: History Control Page
Page 115

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fs752ts

Table of Contents