Error Code
28-46-0-0
Diagnosis Appears
PROFINET Alarm received
(Alarm contains only
Maintenance status).
28-47-0-0
Diagnosis Disappears
PROFINET Alarm received
(Alarm contains only
Maintenance status).
28-48-0-0
Diagnosis Appears
PROFINET Alarm received.
28-49-0-0
Diagnosis Disappears
PROFINET Alarm received.
28-50-0-0
PROFINET Status Alarm
received.
28-51-0-0
PROFINET Update Alarm
received.
28-52-0-0
Port Data Change PROFINET
Alarm received (Alarm
contains manufacturer
specific data).
18
28-53-x-0
Port Data Error Appears
PROFINET Alarm received.
18
28-54-x-0
Port Data Error Disappears
PROFINET Alarm received.
18
28-55-x-y
Port Data Error Appears
PROFINET Alarm received
(Alarm contains Extended
Channel Data).
18
28-56-x-y
Port Data Error Disappears
PROFINET Alarm received
(Alarm contains Extended
Channel Data).
18
28-57-x-y
Port Data Error Appears
PROFINET Alarm received
(Alarm contains Qualified
Channel Data).
GFK-2816F
Description
A PROFINET Alarm has been
received indicating that a
diagnostic condition has been
detected on the PROFINET device.
A PROFINET Alarm has been
received indicating that a
diagnostic condition has been
resolved on the PROFINET device
and maintenance is no longer
required.
A PROFINET Alarm has been
received indicating that a
diagnostic condition has been
detected on the PROFINET device.
A PROFINET Alarm has been
received indicating that a
diagnostic condition has been
resolved on the PROFINET device.
A PROFINET Alarm has been
received indicating a status change
on the PROFINET Device.
A PROFINET Alarm has been
received indicating a change to an
operating parameter has been
changed outside of the PNC's
control.
A PROFINET Alarm has been
received indicating a Port change
on the PROFINET device.
A PROFINET Alarm has been
received indicating that a Port Error
has occurred on the PROFINET
device.
A PROFINET Alarm has been
received indicating that a Port Error
condition has been resolved on the
PROFINET device.
A PROFINET Alarm has been
received indicating that a Port Error
has occurred on the PROFINET
device.
A PROFINET Alarm has been
received indicating that a Port Error
condition has been resolved on the
PROFINET device.
A PROFINET Alarm has been
received indicating that a Port Error
has occurred on the PROFINET
device.
Cause
August 2015
Chapter 14. Diagnostics
Recommended Correction
Consult Device manufacturer
documentation.
Note: Alarm details are
provided in the Fault Extra Data.
None.
Note: Alarm details are
provided in the Fault Extra Data.
Consult Device manufacturer
documentation.
Note: Alarm details are
provided in the Fault Extra Data.
None.
Note: Alarm details are
provided in the Fault Extra Data
Consult Device manufacturer
documentation.
Note: Alarm details are
provided in the Fault Extra Data
Consult Device manufacturer
documentation.
Note: Alarm details are
provided in the Fault Extra Data
Consult Device manufacturer
documentation.
Note: Alarm details are
provided in the Fault Extra Data
Consult Device manufacturer
documentation.
Note: Alarm details are
provided in the Fault Extra Data
None.
Note: Alarm details are
provided in the Fault Extra Data
Consult Device manufacturer
documentation.
Note: Alarm details are
provided in the Fault Extra Data
None.
Note: Alarm details are
provided in the Fault Extra Data
Consult Device manufacturer
documentation.
Note: Alarm details are
provided in the Fault Extra Data