6-4-2. Alarm lower limit

alarm lamp comes on if the item set in [ALARM MODE] falls short of this set
LO
value (
LO
LO turns ON.
This value is ignored if "COMPARISON OFF" is selected in [ALARM MODE].
Operation
MODE
Range: 0 – 999.99% (5 digits, decimal place fixed)

6-4-3. Alarm mode

Use this menu item to specify which parameter (Feed Ratio or Load Ratio) is to be
compared with the upper and lower limit.
is displayed if "COMPARISON OFF" is selected.
OFF
Operation
MODE
Options: COMPARISON OFF, FEED RATIO, LOAD RATIO

6-4-4. Total final

Total final over occurs when TOTAL becomes greater than TOTAL FINAL and the
external output signal TOTAL FINAL OVER (pin 44) turns on accordingly. If the main
arithmetic field is selected to display TOTAL, the message
displayed (reversed red) in the field. If feed rate is selected for the main arithmetic
field,
TOTAL OVER
This message goes out when [TOTAL WEIGHT CLEAR] is executed, and the output
signal is reset to its original state.
This message and output signal are also reset if "ALARM&CONTINUE" is selected in
[TOTAL FINAL MODE] and the total final value overflows beyond nine digits and
zero-cleared.
Operation
MODE
Range: 0 – 999999999 (9 digits, decimal place floating)
is displayed in reversed red while RUNNING), and the external output
COMPARISON
→ ALARM LOWER LIMIT
COMPARISON
→ ALARM MODE
is displayed in the sub-arithmetic field in reversed red.
COMPARISON
→ TOTAL FINAL
6.SETTING AND ADJUSTMENT OF READING
TOTAL OVER