4-6. External I/O Connector
F805AT-BC uses a 50-pin amphenol connector for the external I/O connector.
Compatible plug is DKK 57-30500 (supplied) or its equivalent. For more information,
"CONTROL SIGNAL (External I/O Connector)" , on page 95.
4-6-1. Pin assignment
1
*
2
IN
3
IN
4
IN
5
IN
6
IN
7
IN
8
IN
9
IN
10
*
11
IN
12
IN
13
IN
14
IN
15
*
16
*
17
OUT PULSE OUTPUT1
18
OUT PULSE OUTPUT2
19
OUT UPPER LIMIT(HI)
20
OUT GO
21
OUT LOWER LIMIT(LO)
22
OUT WEIGHT ERROR
23
OUT BELT MOVING
24
OUT POWER ON
25
*
* COM: following pins are connected together inside the instrument: 1, 10, 15, 16, 25,
26, 35, 40, 41, and 50.
* Supply voltage is not available from this terminal.
COM
RUNNING
DISP1 CHANGE1
DISP1 CHANGE2
DISP1 CHANGE4
DISP2 CHANGE1
DISP2 CHANGE2
DISP2 CHANGE4
T.WT.CLEAR
COM
CODE# DESIGNATION1
CODE# DESIGNATION2
CODE# DESIGNATION4
CODE# DESIGNATION8
COM
COM
COM
4.SIGNAL CONNECTION
26
COM
*
27
IN
DZ
28
IN
ZERO POINT
AUTO ADJUSTMENT
29
IN
TEST MODE
SPAN MEASUREMENT
30
IN
PULSE COUNT START
31
IN
PULSE COUNT STOP
32
IN
OPERATION MODE 1
33
IN
OPERATION MODE 2
34
IN
GRAPH DRAWING
35
COM
*
36
IN
CODE# DESIGNATION10
37
IN
CODE# DESIGNATION20
38
IN
CODE# DESIGNATION40
39
IN
CODE# DESIGNATION80
40
COM
*
41
COM
*
42
OUT RUNNING
43
OUT NZ
44
OUT TOTAL FINAL OVER
45
OUT ZERO ERR. MEASURING
46
OUT ZERO ERR. MEAS. OK
47
OUT ZERO ERR. MEAS. NG
48
OUT FEED RATE OVER
49
OUT FEED RATE UNDER
50
COM
*
21