8-4-5. D/A full scale

This menu item specifies, for each channel, physical values corresponding to 20mA
current output. The units for these values is determined automatically with the selection
in 9-3-3. If "CONTROL RATE" is selected in [D/A OUTPUT MODE], allowable input
ranges from 0.0 to 100%.
Operation
MODE
→ PAGE
Input range: 1-99999 (5 digits, decimal place automatically determined)

8-4-6. D/A output compensation

If you use a vibration feeder for the receiver of control value, the feeder output does not
change in right proportion with the control value. This menu input is used to
compensate the discrepancy: zero point is lifted by the amount specified in this menu
(only for "CONTROL RATE"). This value can be specified separately for each
channel.
100
75
50
25
Operation
MODE
→ PAGE
Input range: 0.0– 100.0% (4 digits, decimal place fixed to 1)
OPTION
0.0– 100.0% (4 digits, decimal place fixed)
without output compensation