15. SPECIFICATIONS

15-1. Analog

Load cell excitation:
Zero/span adjustment:
Min.input resolution:
Accuracy:
Analog filter:
A/D converter
Min. display resolution
Secondary calibration

15-2. Display

Display
Arithmetic display
Display update rate
Weighing capacity
Min. scale division
Dicimal point
DC 10V±5% (5V or 10V selectable) Source current < 120mA
Remote sensing
(Up to four 350Ω load cells can be connected in parallel)
Zero adjustable range:
Span adjustable range:
0.3μV/count
Linearity error:
<0.01% FS
(Typ. 0.005% FS, room temperature)
Zero drift:
<0.1μV/ ℃ RT1 (Typ. 0.08μV/ ℃)
Gain drift:
<15ppm/ ℃ (Typ. 5 ppm/ ℃ )
<
Noise
0.1μVp-pRTI(0.1Hz - 10Hz)
Bessel type low-pass filter (-12dB/oct)
selectable from 2, 4, 6, 8 Hz
conversion rate:
200times/sec.
resolution:
16 bit (binary)
1/10000
Equivalent input
resolution: 1/1000 (room temperature)
TFT color LCD
area:
116.8 (W)×88.0 (H) mm
dot configuration:
320×240
dot pitch:
0.12 (W)×0.36 (H) mm
5/9 digits
sign:
'-' is displayed on the leading digit.
Selectable from 1, 3, 6, 13, 25 times/sec
(A/D conversion rate fixed)
up to 5 digits
1 – 100 selectable
selectable
(zero blanking at the decimal point)
15.SPECIFICATIONS
0 – approx.2mV/V
0.3 – 2.0 mV/V
171