6.SETTING AND ADJUSTMENT OF READING
[Main arithmetic display: TOTAL]
6-4-5. Total final mode
Use this menu item to select if the Total Final value is to be compared with the set
values.
COMPARISON OFF:
ALARM&CONTINUE:
ALARM&STOP:
Operation
MODE
Options: COMPARISON OFF, ALARM&CONTINUE, ALARM&STOP
6-4-6. Belt speed over
Over scale alarm "OFL1" is activated when the belt speed becomes greater than BELT
SPEED OVER set value. Comparison is disabled if the value is set to 999.99. Also, the
comparison is disabled if [BELT SPEED OVER ASC.] is set to zero second.
Operation
MODE
Range: 0 – 999.99 m/min (5 digits, decimal place fixed)
62
comparison with [TOTAL FINAL] set value is disabled.
the run continues if TOTAL FINAL OVER occurs.
the run stops if TOTAL FINAL OVER occurs.
Total pulse output continues if TOTAL calculation
comes to a halt.
COMPARISON
→ TOTAL FINAL MODE
→
COMPARISON
→ BELT SPEED OVER
→
[Main arithmetic display: FEED RATE]