7.CONTROL SIGNAL (External I/O Connector)

7-5-9. Running

This output is ON while the system is operating (measuring).
7-5-10. NZ
This output turns ON (only while RUNNING) when DEAD BAND LOAD RATIO [%]
is greater than LOAD RATIO [%]

7-5-11. Total final over

This output turns ON (only while RUNNING) when Total is greater than the set value
of Total Final. Note that "COMPARISON OFF" in [ALARM MODE] suppresses this
alarm.

7-5-12. Zero error measuring

This output turns ON while zero point auto adjustment is being carried out.

7-5-13. Zero error measure OK

This output turns ON for one second when zero measurement normally ends and the
zero error point data is updated. It does not turn on if zero measure failed.

7-5-14. Zero error measure NG

This output turns ON for one second when zero measurement failed or aborted. Zero
error point date will not be updated.