Rs-232C Interface; Communication Specifications - Unipulse F805AT-BC Operation Manual

Belt scale controller
Table of Contents

Advertisement

Assigning ID number (SI/F II ID)
This function defines the F805AT-BC's ID number on the SI/F II network. Enter the
desired ID number and press
Operation
MODE
Input Range: 0-3

8-3. RS-232C Interface

8-3-1. Communication specifications

Specifications
Signal Level:
Transmission Distance: Approx. 15 m
Transmission method:
Transmission speed:
Bits configuration:
Communication code:
Connector pin assignment
Compatible plug: 9-pin D-type Subminiature
1
2
IN
3
OUT
4
OUT
5
to confirm.
OK
PAGE →
COMMUNICATION
RS-232C compatible
Asynchronous, full-duplex
1200, 2400, 4800, 9600, 19200, or 38400 (selectable)
Start bit:
Character length:
Stop bit:
Parity:
ASCII
* OMRON XM3D-0921
(Shell: XM2S-0913 <screw: #4-40 (inch)>) or equivalent
6
RXD
7
TXD
8
DTR
9
GND
→ PAGE
→ SI/FⅡ ID
1
7 or 8 (selectable)
1 or 2 (selectable)
none, odd or even (selectable)
IN
DSR
OUT
RTS
IN
CTS
8.INTERFACE
105

Advertisement

Table of Contents
loading

Table of Contents