Setting range and code No. of each set value

■Upper Limit/ Lower Limit/ Near Zero (Setting Code 06 to 08)

These settings are for feed/discharge control, and direct comparisons are made with these values
irrespective of the final value.
Setting range and code No. of each set value
■Over/Under Comparison/ Upper/Lower Limit Comparison/
Near Zero Comparison (Setting Code 20 to 22)
For each comparing point such as final, the comparing weight (gross weight or net weight) and
timing can be selected. The following three items are selectable.
1) Over/under comparison (Code No.20)
Select the weight value for Over/under comparison.
Setting/ 0: Gross weight  1: Net weight  2: Comparison OFF
2) Upper/Lower limit comparison (Code No.21)
Select the weight value for upper/lower limit comparison.
Setting/ 0: Gross weight  1: Net weight  2: Comparison OFF
3) Near zero comparison (Code No.22)
Select the weight value for near zero comparison.
The Near Zero signal turns ON when the comparing weight ≦ near zero set value.
Setting/ 0: Gross weight  1: Net weight  2: Comparison OFF  

■Over/Under Comparison Mode (Setting Code 27)

Setting/ 0: Continuous comparison
35
Set value
Setting range
Final
00000 to 99999
Set point 1
00000 to 99999
Set point 2
00000 to 99999
CPS
0000 to 9999
Over
000 to 999
Under
000 to 999
Set value
Setting range
Upper limit
Lower limit
00000 to 99999
Near zero
3: |Gross weight|  4: |Net weight|
1: Comparison when the external judgment input is ON
2: Comparison when the complete output is ON
3: Comparison, holding the weight value, when the complete output is ON
Initial value
Code No.
00000
00
00000
01
00000
02
0000
03
000
04
000
05
Initial value
Code No.
06
00000
07
08
5 FUNCTIONS
Chapter
5
35

Advertisement

Table of Contents
loading