6.SETTING AND ADJUSTMENT OF READING
6-4-10. Feed ratio over
Over scale alarm "OFL5" is activated when the feed ratio becomes greater than FEED
RATIO OVER set value. Comparison is disabled if the value is set to 999.99. Also, the
comparison is disabled if [FEED RATIO OVER ASC.] is set to zero second.
Operation
MODE
Range: 0 – 999.99 % (5 digits, decimal place fixed)
6-5. Graph Setting
6-5-1. Bar graph screen
End point setting
Specifies end points for bar graphs
6-5-2. Belt speed end point
Use this item to specify the full-scale value for belt speed bar graph.
Operation
MODE
Range: 0.01 – 999.99 m/min (5 digits, decimal place fixed)
64
→
COMPARISON
→
Screen select key
Goes to comparison screen
Bar graph
GRAPH SETTING
→
PAGE
→ FEED RATIO OVER
Graph select key
Goes to waveform display
Bar graph end point
→ BELT SPPED END POINT
Goes to
Mode selection
screen
Bar graph area