Initial Dead Load - Unipulse F805AT-BC Operation Manual

Belt scale controller
Table of Contents

Advertisement

5.CALIBRATION

5-6-10. Initial dead load

Enter and store the initial zero point by value.
Register the load cell's initial dead load (mV/V).
Make sure that
"Equivalent calibration".
Operation
Press [INITIAL DEAD LOAD]
1)
Enter the load cell output value corresponding to the initial dead load, and press
2)
OK
Pressing
3)
to flicker.
When the settings are finished, the instrument will beep and
change to
If an error message appears on the screen, take an appropriate measure to remove
the error and retry the calibration.
Calibration data is stored in non-volatile RAM. Wait until
4)
changes to
See"TROUBLESHOOTING" , on page 157 for the details of calibration
errors.
Initial load setting should be considered as a simplified version of zero
adjustment.
Use the procedure described in "Zero calibration" , on page 31 for better
accuracy.
38
indicator is off and follow the same steps described in
RUN
.
changes the screen to the comparison display, and
OK
.
RUN
before you can turn off the instrument.
RUN
starts
CALZ
indicator will
CALZ
indication
NOV