Function; Total Weight Clear; Start/Stop Key; Digital Zero (Dz) - Unipulse F805AT-BC Operation Manual

Belt scale controller
Table of Contents

Advertisement

6.SETTING AND ADJUSTMENT OF READING

6-2. Function

6-2-1. Total weight clear

This function clears the Total Weight (this function is disabled while the system is
running).
Operation
MODE
Options: NO, YES

6-2-2. Start/Stop key

This function enables/disables
These keys appear on the upper pane of comparison and message screen. Note that
these keys are activated only when KEY POW.C. ON or KEY POW.C.OFF has been
selected in [OPERATION SELECT].
Operation
MODE
Options: INVALID, VALID

6-2-3. Digital zero (DZ)

This function reset GROSS WEIGHT value to zero. Performing Digital Zero while the
gross weight exceeds the value specified by [DZ REGULATION VALUE] gives rise to
an alarm (
When this alarm appears, the value set to [DZ REGULATION VALUE] will be
automatically subtracted from the gross weight.
Operation
MODE
Options: NO, YES
DZ function can be controlled using one of the external signals connected to the rear
panel I/O connector (27 pin).
External input
(27 pin)
54
FUNCTION
TOTAL WEIGHT CLEAR
START
FUNCTION
→ START/STOP KEY
is displayed in red reverse mode).
ZALM
FUNCTION
→ DIGITAL ZERO
Digital Zero-ON
and
STOP
keys to start/stop the operation.
Digital Zero-ON
★ Pulse width > 50 ms

Advertisement

Table of Contents