Every 2 Years/Every 500 Operating Hours; Changing The Hydraulic Oil - Fayat Group DYNAPAC DRP25D Original Operating Instructions

Reversible plate
Table of Contents

Advertisement

8.10

Every 2 years/every 500 operating hours

8.10.1

Changing the hydraulic oil

Fig. 113
Fig. 114
Fig. 115
Maintenance – Every 2 years/every 500 operating hours
Protective equipment:
1.
Park the machine safely
in secured condition' on page 59.
2.
Move the steering rod to an upright position and engage the
locking pawl lever securely.
B-695-0129
3.
Clean the area around the filler plug and unscrew the filler
plug.
B-695-0015
4.
Press the handle forward against the stop and secure it in
this position using suitable means.
B-695-0016
DRP25D
n
Working clothes
n
Safety shoes
n
Protective gloves
Ä Chapter 6.4 'Parking the machine