VERSION 05/2012
OPERATING MANUAL
8.8
CORONA-STAR FOR ANGLE ADAPTER
8.8.1
MOUNTING THE CORONA-STAR
Danger from electric current!
Risk of injury and damage to the device.
2
P_01169
ORDER NUMBER DOC 390829
WARNING
Only trained personnel may modify the Corona-Star.
Prior to mounting the Corona-Star, the high-voltage and
the powder feed must be switched off and secure against
inadvertent switch on.
1
3
PEA-C4-HiCoat
Procedure:
1. Switch off the high-voltage and the powder
feed and secure against inadvertent switch
on.
2. Remove stopper from gun housing.
3. Fit Corona Star for angle adapter 2 on angle
adapter (direction of fi tting shown is example
only).
4. Fix the connection cable 3 on the spray gun
housing.
Note:
Check whether the grounding is assured.
5. The spray gun is ready for use again.
Note:
Put stopper back into hole in gun housing when
converting the gun in the normal version without
angle adapter.
46