VERSION 05/2012
OPERATING MANUAL
8.6

FITTING THE ANGLE ADAPTER

8.6.1

REMOVING THE NOZZLE AND ELECTRODE HOLDER

The standard Corona spray gun is delivered with a fl at spray nozzle. The nozzle can be
changed easily, as described below.
Note:
If changing from the fl at spray nozzle to the defl ector cone, the depth control must be
adjusted.
An angle adapter WA90 C4, WA 60 C4 or WA30 C4 is necessary to perform the change, as
listed in chapter 12 "Accessories".
Note:
A fl at spray nozzle as well as a round spray nozzle can be fi tted to the angle adapter.
2
1
P_00591
ORDER NUMBER DOC 390829
3
5
Procedure:
1. Unscrew cap nut 1 from spray gun housing 5.
2. Pull fl at spray nozzle 2 off the electrode holder 3.
3. Carefully remove electrode holder 3 from gun
housing 5.
Note:
Do not damage the electrode holder, when pulling
out and inserting.
4. Remove powder residues from the parts
removed and from the spray gun.
PEA-C4-HiCoat
42