SSSW No.
Bit No.
12
0
1
2
3
4
5
7
13
2
14
2
4
15
2
6
18
0
1
2
22
0
3
25
0
2
3
28
0
1
2
3
4
5
30
5
32
5
33
0
2
5
35
0

18.4.2 MENU

18.4.2.1 MENU List

Number
05
ON/OFF of NL equalizer
06
Telephone line monitor
07
Delivery level (ATT)
08
Upper limit of V.34 modulating speed
09
Upper limit of V. 34 data speed
10
Frequency of pseudo CI signal
(Page timer settings-related)
Time by 2-bit combination
(0, 0): 8 min, (0, 1): 16 min, (1, 0): 32 min, (1, 1): 64min
When bit 7 is 0:
- 1page timeout time is specified with bit 1 and bit 0 regardless of any mode communication.
When bit 7 is 1:
- The timeout time for general transmission is specified with bit 1 and bit 0, for HT transmission with bit 3 and bit 2, for reception with
bit 5 and bit 4
1 page timeout time (transmission)
1 page timeout time (HT transmission)
1 page timeout time (reception)
1 page timeout time
Convert mm/inch when sending received image
Whether executing inch to mm conversion in both main and sub scanning directions, or in sub scanning direction only
Perform inch-type resolution declaration
Accept receiving ND line: Host machine line
Detect continuous signal at F/T switching
Detect carrier disconnection between DCS and TCF
Waiting time for carrier disconnection between DCS and TCF
Forbid communication control for IP network
Forbid delivering NSX
Forbid manual polling operation
(Report display function settings-related)
Prioritize received phone number to dialed number
When receiving blank CSI, regard the CSI as not-received
Message language selection user SW
Forbid V8 procedure at calling side
Forbid V8 procedure at receiving side
Forbid V8 late start at calling side
Forbid V8 late start at receiving side
Forbid fallback start from V.34 receiving side
Forbid fallback start from V.34 sending side
New dial tone detection method
0: NCU2004, 1: NCU2002
(Record) whether to count B4 size as large size or not
(Scan) whether to count B4 size as large size or not
Display toner replacement counter
e-RDS function (0: OFF/1: ON)
Registration mode of menu switch
Parameter
Function
T-18-38
Description of the selection
0: OFF, 1: ON
0: DIAL, 1: SERVICEMAN1, 2: SERVICEMAN2, 3: OFF
0-15
0: 3429BAUD, 1: 3200BAUD, 2: 3000BAUD,
3: 2800BAUD, 4: 2743BAUD, 5: 2400BAUD
(Unit: kbps)
0: 33.6, 1: 31.2, 2: 28.8, 3: 26.4, 4: 24.0,
5: 21.6, 6: 19.2, 7: 16.8, 8: 14.4, 9: 12.0,
10: 9.6, 11: 7.2, 12: 4.8, 13: 2.4
0: 50 Hz, 1: 25 Hz, 2: 17 Hz