Chapter 4

4.5 Parts Replacement Procedure

4.5.1 Main Controller PCB

4.5.1.1 Before Removing the Main Controller PCB

1) Remove the ETB unit.(page 8-30)Reference [Removing the ETB Unit]
2) Remove the rear cover unit.(page 11-11)Reference [Removing the Rear
Cover Unit]
3) Remove the left cover.(page 11-13)Reference [Removing the Left Cov-
er]
4) Remove the right cover.(page 11-11)Reference [Removing the Right
Cover]
5) Remove the Electrical Components Cover.(page 11-15)Reference [Re-
moving the Electrical Components Cover]
6) Remove the Controller Box.(page 11-15)Reference [Removing the
Controller Box]

4.5.1.2 Removing the Main Controller PCB

1) Remove the face cover [1].
- 1 screw [2]
[2]
[1]
2) Remove the NCU frame [1].
- 1 flat cable [2] (only of the machine with FAX)
- 1 connectors [3] (only of the machine with FAX)
- 1 connectors [4]
- 6 screws [5]
[5]
[5]
[1]
[3]
3) Remove the Main controller PCB [1].
- 2 connectors [2]
- 10 screws [3]
4-12
F-4-15
[5]
[4]
[2]
F-4-16
0020-3324
[2]
0020-3325
Points to Note When Replacing the Main Controller
- If the RAM [4] is installed in the main controller PCB, remove it.
- If a RAM is not installed in the new main controller, install the removed
RAM [4].
4.5.1.3 Procedure after Replacing the Main Controller
PCB
After replacing the main controller PCB with new one, perform the follow-
ing procedure.
1. Backup the user data
Import the user data using the remote UI.
The machine does not support "Import/export via USB" (provided in the
following service SW) because it supports network as standard function.
# COPIER->FUNCTION->PARAM->SYS-SW->Bit Switch->SW 02 Bit6
2. Enter the flicker adjustment value of the control panel
1) Using the service mode, check the flicker value of the control panel.
TESTMODE> PANEL> FLICKER CHECK START> FLICKER AD-
JUST
MEMO:
The flicker adjustment value can be also checked in the spec list (FLICKER
ADJ PRM).
How to output the spec list: COPIER> FUNCTION> MISC-P> OUTPUT>
SPEC
2) Replace the main controller PCB.
3) Using the service mode, enter the adjustment value checked in Step 1).
TESTMODE> PANEL> FLICKER CHECK START> FLICKER AD-
JUST
4) Using the user mode, execute automatic gradation correction (full correc-
tion).
Initial Setting/Registration> Adjustment/Cleaning> Automatic Gradation
Correction> Full Correction
[3]
[3]
F-4-17
T-4-4
[1]
[4]
0021-0348