Canon iR C1020 Series Service Manual page 373

Advertisement

Sub item
CST-U1
Not used
CST-U2
Not used
CST-U3
Not used
<ACC>
Sub item
COIN
ON/OFF setting for the coin vendor display
- Change the message on the control panel prompting an operator to set a control card to the one prompting him/her to insert a coin.
Setting value:
0: Default message; "Set a control card."
1: Message for a coin vendor; "Insert a coin."
[Factory setting value/Value after RAM clearing: 0]
CARD
Setting for installation of the new card reader
Enter a card number.
Setting range: 0 to 99999
[Factory setting value/Value after RAM clearing: 0]
When a card number is entered, the following settings are made.
- Initialize the information registered for department management.
- Register the following number of cards based on the card number entered.
MF9130/MF9150c/MF9170/MF9170C/MF9330C/MF9340C/MF9340C/MF9370C/iR C1021/iR C1021i/iR c1022/iR C1022i/iR C2110F/iR
C2110N:
1000 cards
MF8450/MF8450C:
100 cards
However, the number of usable IDs is 99999 maximum.
- When 0 is specified for the card number, the department ID is registered from 1.
CONTROL
Control of PDL printer output
Setting value: 0: Perform printing without a card. 1: Perform printing when a card is inserted.
[Factory setting value/Value after RAM clearing: 0]
CC-SPSW
Setting of whether or not to support the control card I/F (CC-V)
Setting value: 0: Do not support the control card I/F. 1: Support the control card I/F.
[Factory setting value/Value after RAM clearing: 0]
<INT-FACE>
Not used
<ASSPST-D>
Not used
<ASSPST-P>
Not used
<LCNS-OF>
Disabling no transfer of license
- ST-xxxx, Display of the installation status
Sub item
ST-SEND
Display of the installation status of the Send function when disabling no transfer
Setting value: 0: ON, 1: OFF
[Factory setting value/Value after RAM clearing: 0]
ST-BRDIM
Display of the installation status of BarDIMM when disabling no transfer
Setting value: 0: ON, 1: OFF
[Factory setting value/Value after RAM clearing: 0]
ST-ERDS
Display of the installation status of the 3rd party extended function for ERDS when disabling no transfer
Setting value: 0: ON, 1: OFF
[Factory setting value/Value after RAM clearing: 0]
ST-PCL
Display of the installation status of PCL when disabling non transfer
Setting value: 0: ON, 1: OFF
[Factory setting value/Value after RAM clearing: 0]
ST-EAM
Display of the installation status of EAM when disabling non transfer
Setting value: 0: ON, 1: OFF
[Factory setting value/Value after RAM clearing: 0]
ST-ELA
Display of the installation status of ELA when disabling non transfer
Setting value: 0: ON, 1: OFF
[Factory setting value/Value after RAM clearing: 0]
<LCNS-TR>
T-18-25
COPIER > OPTION > CST
Description
T-18-26
COPIER > OPTION > ACC
Description
T-18-27
COPIER > OPTION > LCNS-OF
Description
Chapter 18
18-25