Download Print this page

Etb Motor; Before Removing The Etb Motor; Removing The Etb Motor - Canon iR C1020 Series Service Manual

Advertisement

2) While pushing the ETB lock lever [1] (2 points at left and right), remove
the ETB unit [2].
Points to Note At Handling
Be careful not to touch the surface of the ETB belt or damage it.
Dirts or small cuts on the belt may cause image faults.
[1]
F-8-70
[1]
[2]
[1]
F-8-71
When closing the front cover with the ETB unit removed and then and
opening it, the drawer connector [1] faces upward. The drawer connector
facing upward may cause the following symptoms; and therefore, be sure to
put down the 2 drawer connectors [1] if necessary.
- When the toner cartridge is not removed
The shutter of the toner cartridge is opened, resulting in deteriorated
sensitivity of the photosensitive drum.
- When the toner cartridge is removed
The coupling [2] and lock mechanism [3] of the toner cartridge works
together and the toner cartridge cannot be installed.
[3]
[2]
[1]

8.5.5 ETB Motor

8.5.5.1 Before Removing the ETB Motor

1) Remove the ETB unit.(page 8-30)Reference [Removing the ETB Unit]

8.5.5.2 Removing the ETB Motor

1) Remove the duplex delivery assembly [1].
- 2 screws [2]
2) Remove the ETB right cover [1]
-3 screws [2]
-5 claws [3]
Chapter 8
[1]
F-8-72
0019-5795
0019-5798
8-31