Profile Series v.N1 Cylindrical Lock

Specifications

4
• Stainless steel, 3⁄4" projection, one-piece
• Guardbolt - Stainless steel, non-handed
• H anded
• O utside lever controlled by any combination of
keypad or proximity
Operating Voltage
Current Draw
Relay Contacts
Data A, Data B Cable
(Between Controller and Interface Module)
Power Supply Cable
DPS, RTE (Between Access Control and Interface Module)
Lock Input Cable
(Between Access Control and Interface Module)
Wiegand Data Cable (Data 0 and Data 1)
(Between Access Control and Interface Module)
LED and Sounder Control Cable (Between Access
Control and Interface Module)
Hinge Transmission
Interface Module Dimensions
Aux Relay Board Dimensions
Operating Temperature
Compatible Proximity Cards
2
800-810-WIRE (9473) • www.sargentlock.com • A0806B
• Inside lever retracts latch
• Locks furnished for 1-3/4" doors. Can be
furnished for other door sizes upon request.
Consult factory
• U.L. Listed (3 hr.)
Electrical
12 or 24 VDC
Controller : 46mA (Max) / Interface Module : 182mA (Max)
Aux Relay Board : 386mA (Max)
All 12 VDC Lockbodies : 500mA (Max)
All 24 VDC Lockbodies : 250mA (Max)
12-24VAC/DC; 1A (max)
Cable
RS 485 Capable
BELDEN 9841 or Suitable Equivalent
18 AWG – 22 AWG (Dependent upon Distance) Stranded
18 AWG – 22 AWG (Dependent upon Distance) Stranded and Shielded
18 AWG – 22 AWG (Dependent upon Distance) Stranded
18 AWG – 22 AWG (Dependent upon Distance)
Stranded and Shielded
18 AWG – 22 AWG (Dependent upon Distance)
Stranded and Shielded
McKinney QC-8 Hinge for Power and Data Communication
Mechanical
4" x 6" (12 x 12 Utility Box)
4" x 6" (Installed in the 12 x 12 Utility Box)
Miscellaneous
-35°C to +66°C (-31°F to + 151°F)
HID format cards 26 to 39 bits in length