Install the optional riser board in the riser cage.
9.
10. Install the following, as needed:
Expansion boards
GPU
Controllers
11. Install the riser cage.
12. Install the access panel.
13. Install the server in the rack.
14. Connect each power cord to the server.
15. Connect each power cord to the power source.
16. Power up the server.

Installing the NVMe M.2 riser option

Prerequisites
Before installing this option, be sure that you have the following:
The components included with the hardware option kit
M.2 drives
T-15 Torx screwdriver
Procedure
Power down the server.
1.
Remove all power:
2.
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
Do one of the following:
3.
a. Extend the server from the rack.
b. Remove the server from the rack.
Remove the access panel.
4.
Remove the primary PCI riser cage.
5.
Hitachi Advanced Server HA810 G2 User Guide
72