Remove The Secondary Pci Riser Cage - Hitachi Advanced Server HA810 G2 User Manual

Table of Contents

Advertisement

Remove the secondary PCI riser cage

Procedure
1. Observe the following alert:
CAUTION: To prevent damage to the server, power down the server and remove all AC power cords
before removing or installing the PCI riser cage.
2. Back up all server data.
3. Power down the server.
4. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
5. Do one of the following:
a. Extend the server from the rack.
b. Remove the server from the rack.
6. Remove the access panel.
7. If needed, remove the primary riser cage.
8. Disconnect any cables connected to the riser cage.
9. Remove any expansion boards installed in the riser cage.
10. Remove the riser cage.
Hitachi Advanced Server HA810 G2 User Guide
33

Advertisement

Table of Contents
loading

Table of Contents