RIGHT PANEL
Universal Power Supply 24VDC
Purpose: The power supply accepts an incoming
voltage range of 88 to 264vac and steps and con-
verts it down to a low output D/C voltage. The unit is
adjusted by the potentiometer to put out 24.0VDC.
The 24VDC goes to the High Voltage Board and to
the Input/Output board.
TEST INSTRUCTION
Volt/Ohm Meter - Voltage Check
Step 1: Disconnect or unplug machine from power.
Step 2: Remove right panel to access power supply
board board/24VDC.
Step 3: Connect power to machine.
Step 4: Enable main On/Off switch.
Step 5: Locate the LED on the left power supply
board (24VDC). An illuminated green led
indicates the unit has incoming power.
Step 6: Check input voltage at the power supply.
Step 7: Set volt meter on 600VAC, install red
meter lead on terminal labeled "L" and black
meter lead on terminal labeled "N". Reading
must be 208VAC.
Step 8: No 208VAC input - First, verify main power
supply and go to Main On/Off switch test
instruction.
Step 9: Next, check the output voltage at the power
supply.
Step 10: Set volt meter on 200VDC, install red
meter lead on positive (+) terminal and
black meter lead on negative (-) terminal.
Reading must be 24VDC.
Note: Potentiometer adjustment screw
on power board is an adjustment for the
output voltage.
Step 11: No 24.0VDC output - replace power supply.
Note: 24.0VDC present but is interrupted
going to High Voltage board. See Active
Notice icon for Event Codes.
PART RELATES TO THE FOLLOWING SYMPTOMS
User display is not illuminated
Power supply green led is not illuminated
High Voltage Board All Status LED's Not Illumi-
nated