Advertisement

Tank Module
- Removal Instructions (continued)
6
Remove protective harness bushing's from housing.
Remove wiring harness with connectors through holes
that were previously disconnected in Step 3 and 4.
8
The tube coming off the top of the flow meter outlet fitting
going to a "T" connection before the pressure transducer
needs to be disconnected at the "T" fitting.
10
Disconnect each tank temperature sensor 2 pin connector.
NOTE: Document wiring harness color to each
temperature sensor.
7
On top of the "Finish Tank", disconnect the tube from the
outlet fitting.
9
Disconnect the tube at the brew pump inlet elbow
connection.
11
Use a 11/32 nut driver or socket to loosen 2 hex nuts
under the tank module.