Bunn Fast Cup Series Service & Repair Manual page 14

Bean-to-cup single serve brewer
Table of Contents

Advertisement

TROUBLESHOOTING
MACHINE MESSAGES, SYMP-
TOMS and/or ACTIVE NOTICES
Brew Module Active Notices
Piston Not Home,Timeout, Stall , No
Latch or Communication Error
Tank Module Active Notices
25. Inlet, Preheat and Finish Tank Heat
Too Long
26. Inlet, Preheat and FinishTank Sensor
Open or Short
27. Inlet, Preheat and Finish Tank Over
Temperature
PROBABLE CAUSE
c. Piston Motor
d. Wiring Harness
a. Limit thermostat
b. Tank element
c. Solid state relay or wiring connection
issue
d. Temperature sensor
a. Temperature sensor
a. Solid state relay
14
REMEDY
c. Ensure both door switches are in
service mode. Test piston motor for
48.0 VDC
d. Check wiring between piston motor
and input/Output circuit board J16 con-
nector for continuity
a. Reset limit thermostat and investi-
gate why it tripped. Over temperature
or current
b. Check element for proper resistance.
Open - replace tank with element
c. Enter Heaters tab under Service icon.
Test SSR operation by touching test but-
ton to active the SSR. The SSR Green
LED will illuminate when operated and
extinguish when not activated. Current
can be monitored as well during test
d. Check temperature sensor for proper
temperature/resistance range
a. Check wiring harness connection
points before temperature sensor
replacement
a. Solid state relay could e shorted tank
element is drawing current when it sup-
posed to be off
Continued >

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents