1. Regular Inspection for RC700 / RC700-A

This chapter describes maintenance inspection procedures. Performing maintenance
inspection properly is essential to prevent trouble and ensure safety.
Be sure to perform the maintenance inspections in accordance with the schedule.

1.1 Inspections and Schedules

Refer to Functions required for designing - 2. Part Names and Functions for the names
and position of each part.
Inspection
Frequency
Point
Controller
12 months
Emergency
12 months
Stop Button
Safeguard
12 months
Fan Filter
1 months
Fan (Front)
1 months
Fan (Rear)
1 months
Battery
12 months
RC700 Series Rev.3
Regular Inspection 1. Regular Inspection for RC700 / RC700-A
Method
Turn ON/OFF motor and Restart
When the motor turned on,
activate the emergency stop
button
When the motor turned on,
turn on the safeguard
Visual inspection and cleaning
Checking the operating sound
Checking the operating sound
Visual inspection of seven-
segment and LED
Check Item
Activates without any error
Make sure that the seven-segment
LED on the Controller displays
.
Make sure that the seven-segment
LED on the Controller displays
.
No stain
No noise
No noise
No alarm occurred