Functions 3. Installation
3.3 Power Supply
3.3.1 Specifications
Ensure that the available power meets following specifications.
Voltage
Phase
Frequency
Momentary Power
Interrupt
Rated Capacity
100
Item
200 to 240 VAC
(Input voltage should be with in ±10 % of the rated
voltage.)
Single phase
50/60 Hz
10 ms or less
Maximum: 2.5 kVA
Actual power consumption depends on the model, motion,
and load of the Manipulator.
For approximate power consumption of each model, refer
to the following values.
RC700 / RC700-A
RC700DU / RC700DU-A
Refer to the Manipulator manual for rated capacity of the
Manipulator motor.
Specification
C4
: 1.7 kVA
C12
: 2.5 kVA
N6
: 2.2 kVA
G3
: 1.1 kVA
G10
: 2.4 kVA
RS3
: 1.2 kVA
C4
: 1.7 kVA
N6
: 2.2 kVA
G3
: 1.1 kVA
G10
: 2.4 kVA
RS3
: 1.2 kVA
C8
: 2.5 kVA
N2
: 0.6 kVA
G1
: 0.5 kVA
G6
: 1.5 kVA
G20
: 2.4 kVA
RS4
: 1.4 kVA
C8
: 2.5 kVA
G1
: 0.5 kVA
G6
: 1.5 kVA
G20
: 2.4 kVA
RS4
: 1.4 kVA