Allied Telesis x330 Series Installation Manual page 41

Fanless gigabit layer 3 access switches
Hide thumbs Also See for x330 Series:
Table of Contents

Advertisement

x330 Series Installation Guide for Standalone Switches
Warning
Power cord is used as a disconnection device. To de-energize
equipment, disconnect the power cord.
E3
Warning
Class I Equipment. This equipment must be earthed. The power
plug must be connected to a properly wired earth ground socket
outlet. An improperly wired socket outlet could place hazardous
voltages on accessible metal parts.
E4
Note
Pluggable Equipment. The socket outlet shall be installed near the
equipment and shall be easily accessible.
E5
Caution
Air vents must not be blocked and must have free access to the
room ambient air for cooling.
E6
Warning
Operating Temperatures. This product is designed for a maximum
ambient temperature of 45 degrees C.
E57
Note
All Countries: Install product in accordance with local and National
Electrical Codes.
E8
Warning
Only trained and qualified personnel are allowed to install or replace
this equipment.
E14
Caution
Circuit Overloading: Consideration should be given to the
connection of the equipment to the supply circuit and the effect that
overloading of circuits might have on overcurrent protection and
supply wiring. Appropriate consideration of equipment nameplate
ratings should be used when addressing this concern.
E21