Coordinate Resection Measurement - Sokkia 30R Series Operator's Manual

Reflectorless total station
Table of Contents

Advertisement

13. RESECTION MEASUREMENT
13.1

Coordinate Resection Measurement

N, E, Z of an instrument station is determined by the measurement.
• Between 2 and 10 known points can be measured by distance measurement,
and between 3 and 10 known points by angle measurement.
PROCEDURE
1. In the second page of Meas mode
screen, press [MENU], then select
"Resection".
2. Select "NEZ" and press [EDIT] to
input the known point.
After setting the coordinates for
the first known point press { } to
move to the second point.
When all required known points
have been set, press [MEAS].
• When [READ] is pressed,
registered coordinates can be
recalled and used.
"12.1 Entering Instrument
Station Data, PROCEDURE
Reading in Registered
Coordinate Data"
• Press { } to return to the
previous known point.
3. Sight the first known point and
press [DIST] to begin
measurement.
The measurement results are
displayed on the screen.
• When [ANGLE] has been
selected, the distance cannot be
displayed.
52
REM
Resection
Area calculation
Set-out line
Point projection
Resection.
NEZ
Elevation
2 n d P t .
REC
READ
m
MEAS
EDIT
1 s t P t .
=