13. RESECTION MEASUREMENT
8. If there are problems with the
results of a point, align the cursor
with that point and press [BAD].
"*" is displayed on the left of the
point. Repeat for all results that
include problems.
9. Press [RE CALC] to perform
calculation again without the point
designated in step 8. The result is
displayed.
If there are no problems with the
result, go to step 10.
If problems with the result occur
again, perform the resection
measurement from step 3.
• Press [RE OBS] to measure the
point designated in step 9.
If no points are designated in
step 9, all the points or only the
final point can be observed
again.
10. Press [OK] in the screen of step 6
to finish resection measurement.
The instrument station coordinate
is set.
Press [YES] when you want to set
the azimuth angle of the first
known point as the backsight
point.
• Press [NO] to return to Meas
Mode without setting the azimuth angle.
• It is also possible to perform resection measurement when [RESEC] on Meas
mode screen.
Allocating [RESEC]: "24.2 Allocating Key Functions"