Coordinates Setting-Out Measurement - Sokkia 30R Series Operator's Manual

Reflectorless total station
Table of Contents

Advertisement

14.2

Coordinates Setting-out Measurement

After setting the coordinates for the point to be set out, the SET calculates the
setting-out horizontal angle and horizontal distance. By selecting the horizontal
angle and then the horizontal distance setting-out functions, the required
coordinate location can be set out.
• To find the Z coordinate, attach the target to a pole etc. with the same target
height.
PROCEDURE
1. Press [S-O] on the third page of
the Meas mode screen to display
<S-O>.
2. Enter the instrument station data.
"12.1 Entering Instrument
Station Data PROCEDURE
Reading in Registered
Coordinate Data".
3. Set the azimuth angle of the
backsight point.
"12.2 Azimuth Angle Setting"
steps 2 to 6
4. Select "S-O data" and press [ S-
O] until <S-O Coord> is displayed.
14. SETTING-OUT MEASUREMENT
63

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Set230r/r3Set330r/r3Set530r/r3Set630r

Table of Contents